QHR Developers

Get one attendance device

GET/attendance_devices/{id}
Read token is enoughView attendance devices attendance_device/viewRequires feature attendance_deviceAvailable in Claudeattendance_devices.show

Returns one device with the same fields as attendance_devices.list: where it is, what model, whether it is connected, when it last called QHR and last recorded a scan, and how many employees are linked to it.

When to use: to answer questions about a specific device ("is the Riyadh gate online?"), or before attendance_devices.update to see the current values.

Prerequisites: the device id, from attendance_devices.list.

Side effects: none.

Before you call this

You will need ids that come from these operations:

Parameters

NameInTypeDescriptionExample
idRequiredpathintegerDevice id, from attendance_devices.list.14
Accept-LanguageheaderstringLanguage of messages and translated labels. English when omitted.
Allowed values: ar, en
ar

Response

200 The device.

FieldTypeDescription
idintegerDevice id.
namestringName HR gave the device.
serial_numberstringSerial number printed on the device; how QHR recognises it.
usage_modestringWhat a scan means: check_in_only, check_out_only, or shared (the device or the time of day decides in or out).
Allowed values: check_in_only, check_out_only, shared
usage_mode_effective_fromstring (date)Date the current usage mode applies from, in the device's timezone.
timezonestringIANA timezone the device's clock runs in, e.g. Asia/Riyadh.
connection_statestringawaiting_connection (registered, has never called QHR), online, offline (silent for over an hour) or disabled (switched off on purpose).
Allowed values: awaiting_connection, online, offline, disabled
existing_softwarestringSoftware the company used with the device before QHR, as typed at setup.
manufacturerstringManufacturer name.
modelstringModel name (the name typed at setup for an unlisted model).
firmwarestringFirmware version name.
verified_combinationbooleanTrue when QHR has tested this model on this firmware, or the device has already connected. False only means "not tested yet".
locationobjectWork location the device stands in: id and name.
last_contact_atstring (date-time)Last time the device called QHR, UTC ISO 8601.
last_movement_atstring (date-time)Time of the latest scan, UTC ISO 8601.
linked_employees_countintegerEmployees currently linked to a number on this device.
pending_numbers_countintegerNumbers that scanned on this device and belong to nobody yet.
created_byobjectWho registered the device: id and name.

Errors

HTTPCodeMeaningHow to fix
401token_missingNo Authorization: Bearer … header, or it is malformed.Send Authorization: Bearer qhr_… with the full token.
401token_invalidThe token is unknown or wrong, or its owner's account is locked.Check the token was copied in full, or create a new one in QHR › Settings › API & Integrations.
401token_expiredThe token is past its expiry date.Create a new token.
401token_revokedThe token was revoked by its owner or an admin, or the owner was removed from the company (which revokes all their tokens).Create a new token, or ask your admin. If the owner was removed, they must be re-invited to the company first.
401tenant_inactiveThe company account is suspended.Contact QHR support.
403forbiddenThe token owner's role lacks the permission this operation needs.Ask an admin to grant the permission shown on this operation (x-permission).
403employee_inactiveThe token owner's employee record is not active.HR must reactivate the employee record.
403tenant_access_revokedThe token's owner is no longer an active member of this company. Rare: removing a member normally revokes their tokens, which answers 401 token_revoked instead.The owner must be re-invited to the company, then create a new token. If the owner is still a member, contact QHR support.
404not_foundThe record does not exist, or you cannot see it.Check the id. List the records first to get a valid one.
This endpoint can also return the errors that can happen on any endpoint →402 / 412 / 425 entitlement_blocked · 429 rate_limited · 500 internal_error

See the full error catalogue →