QHR Developers

Register an attendance device

POST/attendance_devices
Needs a read & write tokenConnect, edit and remove attendance devices attendance_device/manageRequires feature attendance_deviceNot available in Claudeattendance_devices.create

Registers a device at a location and answers with the device and its setup card: the server address and port IT enters on the device, and step-by-step instructions for that model in the caller's language. The device stays awaiting_connection until it calls QHR. A serial number can be registered once across QHR.

When to use: when the company installs a new device. Then poll attendance_devices.connection until it is online, and link employees with attendance_device_employee_links.create or the CSV import.

Prerequisites: manufacturer_key, model_key and firmware_key from attendance_devices.catalogue (other with model_name / firmware_name for unlisted hardware); location_id from employees.meta_data (locations).

Side effects: QHR starts accepting scans from this serial number. The device is recorded in the audit log. Not offered to Claude: it is a technical setup that needs someone at the device.

Not available in Claude yet.

Before you call this

You will need ids that come from these operations:

Parameters

NameInTypeDescriptionExample
Accept-LanguageheaderstringLanguage of messages and translated labels. English when omitted.
Allowed values: ar, en
ar

Request body

application/json

FieldTypeDescription
attendance_deviceRequiredobjectThe device.
attendance_device.nameRequiredstringA name people will recognise, e.g. the door it stands at.
attendance_device.location_idRequiredintegerWork location id, from employees.meta_data (locations). Only employees of this location can be linked.
attendance_device.serial_numberRequiredstringSerial number printed on the device.
attendance_device.manufacturer_keyRequiredstringManufacturer key from attendance_devices.catalogue.
attendance_device.model_keyRequiredstringModel key from the catalogue, or other.
attendance_device.model_namestringThe model's name; required when model_key is other.
attendance_device.firmware_keystringFirmware key from the catalogue, or other. Optional.
attendance_device.firmware_namestringThe firmware's name; required when firmware_key is other.
attendance_device.timezoneRequiredstringIANA timezone of the device's clock, e.g. Asia/Riyadh.
attendance_device.usage_modeRequiredstringcheck_in_only, check_out_only or shared.
Allowed values: check_in_only, check_out_only, shared
attendance_device.existing_softwarestringSoftware used with the device before QHR, for reference.

Response

201 The new device, with its setup card.

FieldTypeDescription
idintegerDevice id.
namestringName HR gave the device.
serial_numberstringSerial number printed on the device; how QHR recognises it.
usage_modestringWhat a scan means: check_in_only, check_out_only, or shared (the device or the time of day decides in or out).
Allowed values: check_in_only, check_out_only, shared
usage_mode_effective_fromstring (date)Date the current usage mode applies from, in the device's timezone.
timezonestringIANA timezone the device's clock runs in, e.g. Asia/Riyadh.
connection_statestringawaiting_connection (registered, has never called QHR), online, offline (silent for over an hour) or disabled (switched off on purpose).
Allowed values: awaiting_connection, online, offline, disabled
existing_softwarestringSoftware the company used with the device before QHR, as typed at setup.
manufacturerstringManufacturer name.
modelstringModel name (the name typed at setup for an unlisted model).
firmwarestringFirmware version name.
verified_combinationbooleanTrue when QHR has tested this model on this firmware, or the device has already connected. False only means "not tested yet".
locationobjectWork location the device stands in: id and name.
last_contact_atstring (date-time)Last time the device called QHR, UTC ISO 8601.
last_movement_atstring (date-time)Time of the latest scan, UTC ISO 8601.
linked_employees_countintegerEmployees currently linked to a number on this device.
pending_numbers_countintegerNumbers that scanned on this device and belong to nobody yet.
created_byobjectWho registered the device: id and name.
setupobjectWhat IT types on the device: server_address, server_port and numbered instructions (step, text) in the caller's language.

Errors

HTTPCodeMeaningHow to fix
400bad_requestA parameter is missing or malformed.Check the parameters against this operation's documentation.
401token_missingNo Authorization: Bearer … header, or it is malformed.Send Authorization: Bearer qhr_… with the full token.
401token_invalidThe token is unknown or wrong, or its owner's account is locked.Check the token was copied in full, or create a new one in QHR › Settings › API & Integrations.
401token_expiredThe token is past its expiry date.Create a new token.
401token_revokedThe token was revoked by its owner or an admin, or the owner was removed from the company (which revokes all their tokens).Create a new token, or ask your admin. If the owner was removed, they must be re-invited to the company first.
401tenant_inactiveThe company account is suspended.Contact QHR support.
403token_read_onlyThis token can only read; the operation makes changes.Use a token created with "Allow changes".
403forbiddenThe token owner's role lacks the permission this operation needs.Ask an admin to grant the permission shown on this operation (x-permission).
403employee_inactiveThe token owner's employee record is not active.HR must reactivate the employee record.
403tenant_access_revokedThe token's owner is no longer an active member of this company. Rare: removing a member normally revokes their tokens, which answers 401 token_revoked instead.The owner must be re-invited to the company, then create a new token. If the owner is still a member, contact QHR support.
422validation_failedSome fields are missing or not valid.Fix the fields named in error (and errors when present), then send again.
This endpoint can also return the errors that can happen on any endpoint →402 / 412 / 425 entitlement_blocked · 429 rate_limited · 500 internal_error

See the full error catalogue →